Electrical panel compliance with NF C 15-100 standards: equipment and steps

Bringing your electrical panel up to NF C 15-100 standards: equipment and steps

Electrical panel upgrade to NF C 15-100 standards - EFA France

The NF C 15-100 standard is the French reference for low-voltage electrical installations in residential buildings. Bringing an electrical panel up to code is mandatory when selling a property and recommended for any installation over 15 years old. Here is the complete guide.

Why should you bring your panel up to code?

A non-compliant electrical panel poses significant risks: fire due to overload, electrocution in the event of an insulation fault, and damage to appliances. Furthermore, a non-compliant panel can lead to a refusal of home insurance coverage.

Required equipment

Equipment mandatory under NF C 15-100

  • Main circuit breaker: protects the entire installation (rating based on subscription)
  • 500 mA residual current circuit breaker: fire protection at the head of the panel
  • 30 mA residual current circuit breakers (Type A or AC): per circuit group
  • Surge arrester: mandatory in high lightning strike zones (keraunic level > 25)
  • Neutral and earth distribution block: compliant connection bars

Mandatory circuits

  • 1 lighting circuit per main room (1.5 mm²)
  • 1 socket circuit per room (2.5 mm², max 8 sockets per circuit)
  • Dedicated washing machine circuit (2.5 mm²)
  • Dedicated tumble dryer circuit (2.5 mm²)
  • Dedicated dishwasher circuit (2.5 mm²)
  • Dedicated oven circuit (6 mm²)
  • Dedicated cooktop circuit (6 mm²)
  • Dedicated freezer circuit (2.5 mm²)

Steps to bring your installation up to code

  1. Audit of the existing installation by a Qualifelec-certified electrician
  2. Establishment of the power assessment and the panel schematic
  3. Power shut-off by Enedis
  4. Removal of the old panel
  5. Installation of the new panel with compliant equipment
  6. Verification and testing of the installation
  7. Inspection by the Consuel (National Committee for Electrical User Safety)

Conclusion

EFA France offers all the equipment necessary to bring your electrical panel up to code: circuit breakers, RCDs, surge arresters, and accessories from leading brands (Hager, Schneider, Legrand).

How can we help you?